Product center
產品型號: 1.5P防(fang)爆空(kong)調(tiao)BFKT-3.5
所(suo)屬(shu)分(fen)類(lei):1.5P防爆(bao)空調(tiao)BFKT-3.5
更(geng)新時(shi)間(jian):2025-06-09
簡(jian)要描(miao)述(shu):BFKT-3.5防爆(bao)空調(tiao)、壁(bi)掛式防(fang)爆(bao)空調(tiao)、百科特(te)奧1.5P防(fang)爆空調(tiao)BFKT-3.5。都很(hen)容易導(dao)致(zhi)事故發生。安(an)裝(zhuang)的時(shi)候是室(shi)內室(shi)外外空(kong)調(tiao)機等(deng)電(dian)器(qi)設(she)備的金屬(shu)外殼(ke)壹(yi)定要安(an)裝(zhuang)接地裝置(zhi),但是也(ye)要註(zhu)意(yi)雖然有接(jie)地裝置(zhi),但是電(dian)阻(zu)也(ye)要註(zhu)意(yi)不(bu)能太大(da),同(tong)時(shi)也(ye)要焊(han)接(jie)得夠牢固,不(bu)然還是會(hui)引發事故。防爆空調(tiao)和(he)普通(tong)空調(tiao)有什麽不(bu)同(tong)?與普(pu)通(tong)空調(tiao)不(bu)壹(yi)樣。
BFKT-3.5防(fang)爆(bao)空(kong)調(tiao)、壁(bi)掛式防(fang)爆(bao)空調(tiao)、百科特(te)奧1.5P防(fang)爆空調(tiao)BFKT-3.5。過(guo)冷(leng)液(ye)經毛(mao)細(xi)管阻力降壓後成(cheng)為(wei)低(di)溫低壓兩(liang)相流體,進(jin)入(ru)室(shi)內換(huan)熱(re)器蒸(zheng)發吸熱(此(ci)時(shi)室(shi)內空(kong)氣被降溫(wen)),再壹次(ci)經四(si)通(tong)閥和(he)氣液(ye)分離器進(jin)入(ru)下(xia)壹循環(huan):過(guo)濾(lv)器主要用(yong)於制冷(leng)劑與壓縮機油(you)的分離,
以(yi)保證(zheng)換(huan)熱(re)器(qi)的換熱效率(lv)。當熱(re)泵(beng)型空調(tiao)機運行(xing)於制熱工況(kuang)時(shi),四(si)通(tong)閥換(huan)向使(shi)圖中(zhong)虛(xu)線接通(tong)。這時(shi)、室(shi)內換(huan)熱(re)器成(cheng)為(wei)冷(leng)凝器,室(shi)外換(huan)熱(re)器成(cheng)為(wei)蒸(zheng)發器。
百科特(te)奧防(fang)爆空調(tiao)掛(gua)式櫃式防(fang)爆(bao)等(deng)級:ExdbibmbIIBT4Gb/ExdibmbIICT4Gb可選。
BFKT-2.6(掛式1P防(fang)爆(bao)空調(tiao))制冷(leng)量:2.6kw制熱量(liang)2.7kw適用(yong)面(mian)積(ji)10-15m²
BFKT-3.5(掛(gua)式1.5P防(fang)爆(bao)空調(tiao))制冷(leng)量:3.5kw制熱量(liang)3.8kw適用(yong)面(mian)積(ji)16-24m²
BFKT-5.0(掛(gua)式2P防(fang)爆(bao)空調(tiao))制冷(leng)量:5kw制熱量(liang)6.1kw適用(yong)面(mian)積(ji)20-35m²
BFKT-7.5(掛(gua)式3P防(fang)爆(bao)空調(tiao))制冷(leng)量:7.5kw制熱量(liang)9.3kw適用(yong)面(mian)積(ji)32-50m²
BFKG-5.0(櫃式2P防(fang)爆(bao)空調(tiao))制冷(leng)量:5kw制熱量(liang)6.1kw適用(yong)面(mian)積(ji)20-35m²
BFKG-7.5(櫃式3P防(fang)爆(bao)空調(tiao))制冷(leng)量:7.5kw制熱量(liang)9.1kw適用(yong)面(mian)積(ji)32-50m²
BFKG-12(櫃式5P防(fang)爆(bao)空調(tiao))制冷(leng)量:12kw制熱量(liang)13kw 適用(yong)面(mian)積(ji)40-60m²
BFKG-28(櫃式10P防(fang)爆(bao)空調(tiao))制冷(leng)量:28kw制熱量(liang)42kw適用(yong)面(mian)積(ji)60-120m²
從室(shi)外換(huan)熱(re)器來的低溫低壓(ya)過(guo)熱氣經(jing)四(si)通(tong)閥和(he)消聲(sheng)器(qi)進(jin)入(ru)氣液(ye)分離器,分(fen)離出液(ye)體後(hou),幹(gan)過(guo)熱氣被壓縮(suo)機吸(xi)入(ru)壓縮(suo)成(cheng)為(wei)高(gao)溫高(gao)壓的氣體(ti)徘出,氣體(ti)經(jing)四(si)通(tong)閥進(jin)入(ru)室(shi)內換(huan)熱(re)器放熱(re)冷(leng)凝(此(ci)時(shi),室(shi)內空(kong)氣被加(jia)熱).成(cheng)為(wei)過(guo)冷(leng)液(ye),過(guo)冷(leng)液(ye)經毛(mao)細(xi)管阻力降壓後成(cheng)為(wei)低(di)溫低壓兩(liang)相流體.進(jin)入(ru)室(shi)外換(huan)熱(re)器蒸(zheng)發吸熱,隨後(hou)過(guo)熱氣經(jing)四(si)通(tong)閥和(he)氣液(ye)分離器進(jin)入(ru)下(xia)壹循環(huan)。
BFKT-3.5防(fang)爆(bao)空調(tiao)、壁(bi)掛式防(fang)爆(bao)空調(tiao)、百科特(te)奧1.5P防(fang)爆空調(tiao)BFKT-3.5。為(wei)防(fang)止(zhi)制熱時(shi)因除霜(shuang)導(dao)致(zhi)室(shi)內舒(shu)適性(xing)下(xia)降,采用了(le)熱(re)氣旁通(tong)不(bu)間(jian)斷(duan)制熱除霜(shuang)方(fang)式。除霜(shuang)時(shi),運行(xing)原理(li)基本(ben)與(yu)制熱相同(tong),只是將(jiang)融霜(shuang)電(dian)磁(ci)閥(fa)打開(kai)。從壓(ya)縮機出(chu)來的高(gao)溫高(gao)壓的過(guo)熱氣有壹(yi)部(bu)分被分流到室(shi)外換(huan)熱(re)器的入(ru)口,迅(xun)速把室(shi)外換(huan)熱(re)器的溫度提高(gao)到O℃以(yi)上,融掉室(shi)外換(huan)熱(re)器上(shang)的霜(shuang)層(ceng),使(shi)換熱(re)器保持良(liang)好的換熱效率(lv)。