Product center
產品(pin)型(xing)號:
所屬分(fen)類:5P防爆(bao)空(kong)調BFKG-12
更新時間:2025-06-09
簡(jian)要描(miao)述(shu):百(bai)科特(te)奧BFKG-12櫃(gui)式(shi)防爆(bao)空(kong)調、 櫃(gui)式(shi)5P防爆(bao)空(kong)調、5匹(pi)防爆(bao)空(kong)調BFKG-12系列(lie)機型(xing)通過(guo)特(te)殊的技術加(jia)工(gong)工(gong)藝處理,可(ke)廣(guang)泛應用(yong)於1區(qu),2區防(fang)爆(bao)級別,涵(han)蓋國(guo)防(fang)、科研、石油、化(hua)工(gong)、醫(yi)藥(yao)、加(jia)工(gong)制(zhi)造、生(sheng)物制(zhi)藥(yao)等(deng)多(duo)種(zhong)行業(ye),為(wei)存在(zai)或可(ke)能(neng)存在(zai)ⅡA、ⅡB級,T1~T4組(zu)可燃(ran)性氣(qi)體、蒸(zheng)汽與(yu)空(kong)氣(qi)混合(he)形成(cheng)的易引(yin)發爆(bao)炸的危(wei)險場所,並有(you)溫(wen)度(du)控制(zhi)要求(qiu)場所設(she)計的特(te)種調溫(wen)空(kong)調設(she)備。

百(bai)科特(te)奧BFKG-12櫃(gui)式(shi)防爆(bao)空(kong)調、百(bai)科特(te)奧5P防(fang)爆(bao)空(kong)調、 櫃(gui)式(shi)防爆(bao)空(kong)調、5匹(pi)防爆(bao)空(kong)調BFKG-12。防爆(bao)空(kong)調在(zai)使用(yong)過(guo)程(cheng)中(zhong),制(zhi)冷(leng)系統(tong)並(bing)不(bu)會(hui)頻繁出(chu)現故(gu)障。防(fang)爆(bao)空(kong)調壹旦出現故(gu)障,大(da)家(jia)也(ye)不(bu)要慌(huang)張,只要能(neng)夠按(an)照正(zheng)確的檢(jian)修(xiu)方(fang)法來(lai)對防(fang)爆(bao)空(kong)調進行檢(jian)修(xiu),那(na)麽(me),就(jiu)能(neng)夠根(gen)據實際(ji)情況(kuang)維(wei)修(xiu)好(hao)防爆(bao)空(kong)調,並保(bao)障(zhang)防爆(bao)空(kong)調的正(zheng)常(chang)運行。
夏季(ji)到來(lai)防爆(bao)空(kong)調使用(yong)註意(yi)事(shi)項,夏季(ji)即將(jiang)到(dao)來(lai),隨(sui)著天氣越(yue)來(lai)越(yue)熱,空(kong)調也(ye)即(ji)將(jiang)登(deng)場,那麽(me)使用(yong)空(kong)調都(dou)有(you)哪(na)些註意(yi)事(shi)項呢(ne)?特(te)別是(shi)化工(gong)行業(ye)的防(fang)爆(bao)空(kong)調,下(xia)面小編就(jiu)給(gei)大(da)家(jia)科普(pu)壹(yi)下(xia)。空(kong)調是大(da)功(gong)率(lv)電(dian)器,壹(yi)些廠房(fang)規劃設(she)計時電(dian)線使用(yong)的標號較小,加(jia)上室(shi)外機風吹(chui)日(ri)曬(shai),電(dian)線老(lao)化(hua)嚴(yan)重,會(hui)因(yin)線路(lu)絕緣(yuan)性能(neng)差而引(yin)發火災(zai)或(huo)觸(chu)電(dian)事(shi)故(gu),給人(ren)身和財(cai)產安(an)全(quan)帶(dai)來(lai)隱(yin)患(huan)。因此,防爆(bao)空(kong)調再次(ci)使用(yong)前,要對(dui)其(qi)進行認(ren)真(zhen)檢(jian)查。看(kan)看(kan)電(dian)源插頭(tou)、插座(zuo)有(you)無(wu)發黃、發黑情況(kuang);檢(jian)查室(shi)內外機連(lian)接(jie)線是(shi)否絕(jue)緣(yuan)脫(tuo)落(luo)漏電(dian),確保其(qi)接(jie)觸(chu)良好(hao)。若(ruo)防(fang)爆(bao)空(kong)調長期(qi)停用(yong)。防爆(bao)空(kong)調在(zai)長期(qi)停用(yong)前,應對內部(bu)進(jin)行幹(gan)燥(zao)處(chu)理(li),把主(zhu)控選(xuan)擇(ze)開關(guan)旋到強風處(chu),使風扇高速運(yun)轉(zhuan)4h,把內部(bu)的水(shui)分(fen)吹(chui)幹(gan),然(ran)後關掉(diao)風機(ji),拔(ba)下(xia)電(dian)源插頭(tou),用(yong)塑(su)料布(bu)將(jiang)室外部(bu)分(fen)包紮(zha)好,防(fang)止灰塵(chen)、雜(za)質侵入,室(shi)內部(bu)分(fen)也(ye)用(yong)裝飾布遮蓋,以防室內灰塵(chen)侵入機(ji)內。防爆(bao)空(kong)調使用(yong)階段(duan),為(wei)使室內氣流(liu)暢通,壹般(ban)2~3周對空(kong)氣(qi)過(guo)濾(lv)網清(qing)洗(xi)壹(yi)次,按(an)其(qi)說明(ming)書方(fang)法把空(kong)氣(qi)過(guo)濾(lv)網從(cong)防(fang)爆(bao)空(kong)調器上取下(xia),用(yong)水(shui)沖洗並用(yong)軟(ruan)毛(mao)刷(shua)刷凈(jing),然(ran)後晾幹。積灰不多(duo)時(shi)可用(yong)吸塵(chen)器吸(xi)塵(chen),但(dan)不能用(yong)汽油、揮(hui)發油,酸(suan)類(lei)或高於40℃的熱水(shui)及硬刷(shua)清洗(xi)。空(kong)調器機(ji)殼及面板也(ye)應(ying)經(jing)常(chang)用(yong)軟(ruan)布(bu)抹(mo)去外部(bu)灰塵(chen)及臟(zang)物(wu),如(ru)果汙染太嚴(yan)重,可(ke)用(yong)軟(ruan)布(bu)加(jia)肥(fei)皂水(shui)或(huo)不超過(guo)45℃的溫(wen)水(shui)洗(xi)凈(jing),再(zai)用(yong)軟(ruan)布(bu)擦幹(gan)。重新啟用(yong)。防爆(bao)空(kong)調每(mei)年夏天投入(ru)使用(yong)前,應打開包紮(zha)的塑(su)料布(bu),進(jin)行清(qing)掃(sao)和檢(jian)查。先(xian)按(an)說明(ming)書拆(chai)下(xia)面板和止擋板,用(yong)力拉(la)出機(ji)座(zuo)。用(yong)吸塵(chen)器或(huo)軟(ruan)毛(mao)刷(shua)進行清(qing)掃(sao),特(te)別是(shi)蒸(zheng)發器和冷(leng)凝器翅片上的灰塵(chen),在(zai)清掃(sao)時(shi)不(bu)要碰(peng)壞機(ji)內器件(jian),保持(chi)蒸(zheng)發器和冷(leng)凝器翅片排列(lie)整齊。清掃完畢後,仔細檢(jian)查電(dian)氣線路(lu)的所有(you)接(jie)線有(you)無(wu)松(song)動或(huo)脫(tuo)落(luo)。經(jing)檢(jian)查壹(yi)切(qie)正(zheng)常(chang)後,將機座(zuo)裝(zhuang)入(ru)外殼,通電(dian)試機正(zheng)常(chang)運轉後,才(cai)能(neng)投入(ru)使用(yong)。
百(bai)科特(te)奧BFKG-12櫃(gui)式(shi)防爆(bao)空(kong)調,防爆(bao)空(kong)調系統(tong)調試是指(zhi)空(kong)調冷(leng)負(fu)荷(he)的調試,以各但(dan)系統(tong)調試合(he)格為前提(ti),然(ran)後調試空(kong)調系統(tong),對(dui)空(kong)調範圍(wei)內的環境狀(zhuang)況進(jin)行測(ce)定和調整,環境狀(zhuang)況主(zhu)要包括(kuo)管(guan)理(li)設(she)備的濕度、溫(wen)度(du)、及氣(qi)流(liu)速度(du)、送(song)風溫(wen)度(du)等(deng)方面。
通過(guo)防(fang)爆(bao)空(kong)調系統(tong)系(xi)統(tong)調試過(guo)程(cheng)中(zhong)必(bi)須保證(zheng)系統(tong)在(zai)帶空(kong)調冷(leng)負(fu)荷(he)的情(qing)況(kuang)下(xia),能(neng)連(lian)續(xu)運行八(ba)小(xiao)時(shi)。在(zai)鋪(pu)設(she)管道時,其(qi)他管(guan)道必須首先(xian)以(yi)風管(guan)優先,無(wu)壓管道(dao)優(you)先(xian),為(wei)了(le)能(neng)夠綜(zong)合(he)協(xie)調配合(he),必(bi)須在(zai)現場對實(shi)際(ji)尺寸進(jin)行核(he)實(shi),從(cong)而(er)使得協(xie)調配合(he)工(gong)作(zuo)能(neng)更加(jia)有(you)保(bao)證(zheng)。
其(qi)次空(kong)調的智(zhi)能(neng)化(hua)越(yue)高,對配(pei)電(dian)的要求(qiu)就(jiu)越(yue)高,對弱電(dian)信號傳輸(shu)壓(ya)球高,也(ye)能(neng)起到節能效果。其(qi)次在(zai)技術協(xie)調配合(he)管(guan)理方(fang)面,需把各(ge)個專(zhuan)業(ye)的交(jiao)叉(cha)與(yu)協(xie)調配合(he)工(gong)作(zuo)為(wei)重(zhong)點。要想(xiang)做好管(guan)理協(xie)調,但(dan)從(cong)技術上下(xia)功(gong)夫是不夠的,要建立壹(yi)整套健全(quan)的管(guan)理(li)制(zhi)度,運(yun)用(yong)管理(li)手段(duan)來(lai)減少之(zhi)間存在(zai)的問(wen)題(ti),對(dui)所有(you)環節有(you)壹(yi)個(ge)統(tong)籌(chou)性安(an)排(pai),保(bao)證(zheng)每(mei)個環節之間(jian)配(pei)合(he)密切(qie)。


上壹(yi)篇(pian):5匹(pi)BFKG-12防爆(bao)空(kong)調
下(xia)壹(yi)篇:BFKG-12防爆(bao)空(kong)調