簡要描(miao)述(shu):百(bai)科特奧BFKT-7.5掛式(shi)防爆空(kong)調(tiao)、百科特奧2P防(fang)爆(bao)空(kong)調(tiao)、 壁掛式(shi)防爆空(kong)調(tiao)、2匹防爆(bao)空(kong)調(tiao)BFKT-5.0。防爆空(kong)調(tiao)外觀(guan)基本和(he)家用空(kong)調(tiao)差(cha)不多,按(an)性能(neng)可(ke)分(fen)為單冷和(he)冷(leng)暖(nuan)兩種,按(an)結(jie)構(gou)形(xing)式(shi)可(ke)分(fen)為窗機、分(fen)體壁掛式(shi)、分(fen)體櫃(gui)式三種。不管是炎(yan)熱的(de)夏(xia)季還是寒冷的(de)冬(dong)季,防爆空(kong)調(tiao)都可(ke)以在易燃(ran)易爆危(wei)險(xian)場(chang)合(he)的(de)空(kong)間把(ba)溫度調(tiao)控到(dao)適宜舒(shu)適的溫度。

百(bai)科特奧BFKT-7.5掛式(shi)防爆空(kong)調(tiao)、百科特奧3P防(fang)爆(bao)空(kong)調(tiao)、 壁掛式(shi)防爆空(kong)調(tiao)、3匹防爆(bao)空(kong)調(tiao)BFKT-7.5。安裝註(zhu)意(yi)電(dian)氣安全:使用(yong)電(dian)源空(kong)調(tiao)器(qi)所用(yong)電(dian)源壹(yi)般應(ying)為頻率(lv)50Hz、電(dian)壓在額(e)定電(dian)壓值的90%~110%範圍(wei)以(yi)內(nei)的(de)單(dan)相220V或(和)三相380V交流(liu)電(dian)源。用(yong)戶要有(you)與空(kong)調(tiao)器(qi)相符(fu)的(de)合(he)格電(dian)源,保證電(dian)源容(rong)量足夠(gou)、接地可(ke)靠(kao)和(he)便(bian)於(yu)安裝等(deng)。電(dian)磁(ci)幹(gan)擾(rao)空(kong)調(tiao)器(qi)的室(shi)外機安裝時,應(ying)遠離(li)強烈電(dian)磁(ci)幹(gan)擾(rao)源,室內(nei)機的(de)安裝盡量避(bi)開電(dian)視機、音(yin)響(xiang)等(deng)電(dian)氣器(qi)具(ju),以(yi)防電(dian)磁(ci)幹(gan)擾(rao)。

空(kong)調(tiao)器(qi)的電(dian)氣連接壹(yi)般應(ying)用專(zhuan)用(yong)分(fen)支(zhi)電(dian)路,其容(rong)量應(ying)大(da)於(yu)空(kong)調(tiao)器(qi)zui大(da)電(dian)流(liu)值的(de)1.5倍(bei),其接戶電(dian)線(xian)和進戶電(dian)線(xian)的線(xian)徑(或橫(heng)截(jie)面積(ji))應(ying)按(an)用戶使用(yong)電(dian)量的zui大(da)值選取(qu)。電(dian)源線(xian)路應(ying)安裝漏(lou)電(dian)保護器(qi)或空(kong)氣開關等(deng)保護裝(zhuang)置,空(kong)調(tiao)器(qi)與房(fang)間(jian)內(nei)電(dian)氣布線(xian)應(ying)可靠(kao)地(di)接地,不能隨(sui)意(yi)更改電(dian)源線(xian)。不要隨(sui)意(yi)調(tiao)整(zheng)動力(li)電(dian)源線(xian)的電(dian)源相序(xu)。不能隨(sui)意(yi)去(qu)接電(dian)源線(xian)、連機線(xian)、信號線(xian),電(dian)源連接和外(wai)部軟線(xian)應(ying)符合(he)標(biao)準(zhun)要求(qiu)。用(yong)戶電(dian)源安有插(cha)座時,應(ying)為帶(dai)地線(xian)且(qie)固(gu)定的專(zhuan)用(yong)插座並(bing)應(ying)靠(kao)近空(kong)調(tiao)器(qi)隨(sui)機電(dian)源插(cha)頭(tou)所及(ji)之(zhi)處(chu)。其插座結(jie)構(gou)應(ying)與待(dai)裝空(kong)調(tiao)器(qi)電(dian)源插(cha)頭(tou)相匹(pi)配(pei)並符(fu)合(he)標(biao)準(zhun)要求(qiu)。集中安裝多(duo)臺空(kong)調(tiao)器(qi)時,要註(zhu)意(yi)三相電(dian)源的(de)負(fu)載平(ping)衡,避(bi)免(mian)多(duo)臺(tai)機組裝(zhuang)到三相電(dian)源的(de)同(tong)壹(yi)相中(zhong)。空(kong)調(tiao)器(qi)的接地:空(kong)調(tiao)器(qi)的安裝應(ying)有良(liang)好的(de)接地,接地線(xian)與接地端(duan)子或接地終端(duan)應(ying)緊固連接和妥(tuo)善鎖(suo)緊,不用工(gong)具(ju)就(jiu)不能松(song)開,並符合(he)規定要求(qiu)。不可采(cai)用可(ke)重接的插(cha)頭連接電(dian)源。對(dui)於(yu)zui大(da)工作(zuo)電(dian)流(liu)大(da)於(yu)16A的空(kong)調(tiao)器(qi),應(ying)用漏(lou)電(dian)保護器(qi)或空(kong)氣開關進行與電(dian)源的(de)連接,且(qie)空(kong)調(tiao)器(qi)的電(dian)源線(xian)及保護器(qi)或開關容(rong)量均應(ying)符合(he)空(kong)調(tiao)器(qi)供電(dian)容(rong)量的要求(qiu),以(yi)消除(chu)不安全用電(dian)隱(yin)患(huan)。安全用電(dian)檢查檢查空(kong)調(tiao)器(qi)室內(nei)機、室(shi)外機電(dian)器(qi)元(yuan)件和(he)其他元(yuan)器(qi)件(包(bao)括接線(xian)排(pai)、電(dian)源線(xian)、插座、聯機線(xian)等(deng))有無(wu)老(lao)化(hua),插頭(tou)松(song)動的(de)現(xian)象,用兆(zhao)歐(ou)表檢測絕(jue)緣(yuan)電(dian)阻是否在10MΩ以(yi)上(shang)。對(dui)空(kong)調(tiao)器(qi)的電(dian)源供電(dian)線(xian)路應(ying)提供專(zhuan)用(yong)電(dian)源線(xian)路或開關、插座,電(dian)源線(xian)路材(cai)料(liao)、容(rong)量、絕(jue)緣(yuan)強度、耐(nai)壓等(deng)級(ji)應(ying)符合(he)空(kong)調(tiao)器(qi)設計要(yao)求(qiu)。檢查電(dian)源線(xian)零線(xian)與相線(xian)之(zhi)間(jian)有(you)無(wu)短路。檢查電(dian)源線(xian)的電(dian)源線(xian)徑,供電(dian)容(rong)量,線(xian)路布(bu)線(xian)合(he)理(li)安全性,電(dian)源線(xian)材料(liao)老(lao)化(hua)情況(kuang)。檢查電(dian)源開關,並用測(ce)電(dian)儀檢測電(dian)源插(cha)座,確(que)保電(dian)源火線(xian)、零線(xian)、接地線(xian)正確(que)連接以及(ji)容(rong)量選擇(ze)符合(he)安全使用(yong)要求(qiu),空(kong)調(tiao)器(qi)的使(shi)用條(tiao)件(環(huan)境(jing))必須(xu)滿足(zu)可靠(kao)接地。安裝用(yong)電(dian)檢查。
BFKT-7.5掛式(shi)防爆空(kong)調(tiao)安裝架(jia)機械(xie)強度,承重空(kong)調(tiao)器(qi)安裝架(jia)的承載能(neng)力(li)應(ying)不低於(yu)空(kong)調(tiao)器(qi)機組自(zi)重的4倍(bei),室外機組的(de)安裝架(jia),承載能(neng)力(li)應(ying)不低於(yu)200kg,空(kong)調(tiao)器(qi)室外(wai)機組不能直(zhi)接在材(cai)質(zhi)較松(song)的(de)安裝面上(shang)進行掛壁式(shi)安裝(如(ru)舊(jiu)式房(fang)屋(wu)磚墻、空(kong)心磚墻等(deng));如(ru)必(bi)須采用掛壁式(shi)安裝時,應(ying)充分(fen)考慮安裝面的(de)材質(zhi)強度和(he)承載耐(nai)受力(li)等(deng)因素,采取必要(yao)的(de)加固(gu)或防護措(cuo)施(shi),以(yi)確(que)保空(kong)調(tiao)器(qi)的安全運行和人身(shen)安全。


上(shang)壹(yi)篇(pian):BFKT-7.5防(fang)爆空(kong)調(tiao)
下壹(yi)篇(pian):3匹(pi)BFKT-7.5防爆空(kong)調(tiao)