您(nin)好,歡(huan)迎(ying)來(lai)到杭(hang)州特奧(ao)環保科技(ji)有限(xian)公(gong)司(si)!
Product center
產品型(xing)號: 2P防爆空調(tiao)BFKG-5.0
所(suo)屬分(fen)類(lei):青(qing)島防爆空調(tiao)
更(geng)新(xin)時(shi)間(jian):2025-06-09
簡要描(miao)述:東營百(bai)科特(te)奧(ao)2P防爆空調(tiao)BFKG-5.0、東(dong)營2匹(pi)防爆空調(tiao)廠(chang)家(jia)承重(zhong)空(kong)調器安裝架的(de)承載(zai)能(neng)力應不低(di)於(yu)空調器機組自(zi)重(zhong)的4倍(bei),室外機(ji)組(zu)的(de)安裝(zhuang)架,承載(zai)能(neng)力應不低(di)於(yu)200kg,空調器室外機組(zu)不(bu)能(neng)直接(jie)在(zai)材(cai)質較(jiao)松的安裝面(mian)上進行掛(gua)壁式(shi)安(an)裝(如(ru)舊式(shi)房(fang)屋磚(zhuan)墻(qiang)、空(kong)心磚(zhuan)墻(qiang)等);如(ru)必須(xu)采用(yong)掛(gua)壁式(shi)安(an)裝時,應(ying)充(chong)分考(kao)慮(lv)安裝(zhuang)面(mian)的材(cai)質強度和(he)承載(zai)耐受力等因素,采取必要的(de)加(jia)固(gu)或(huo)防護(hu)措施(shi),以確(que)保空調(tiao)器的安全運行和(he)人身(shen)安全。
東(dong)營百(bai)科特(te)奧(ao)2P防爆空調(tiao)BFKG-5.0、東(dong)營2匹(pi)防爆空調(tiao)廠(chang)家(jia)。當熱(re)泵型空調器運行於(yu)制冷(leng)工(gong)況時(shi),三(san)通(tong)閥(fa)換向(xiang)使(shi)各(ge)部件(jian)接(jie)通(tong)。這(zhe)時,室(shi)內(nei)換(huan)熱器成(cheng)為蒸(zheng)發器,而室外換(huan)熱器成(cheng)為冷(leng)凝器。從(cong)室(shi)內(nei)換(huan)熱器來(lai)的低(di)溫低(di)壓(ya)過(guo)熱(re)氣經(jing)四(si)通(tong)閥(fa)和(he)消(xiao)聲(sheng)器進入(ru)氣液(ye)分離(li)器.
分離(li)出液(ye)體後,經(jing)過(guo)熱(re)氣被(bei)壓縮機吸(xi)入(ru)壓縮成(cheng)為高(gao)溫高(gao)壓的(de)氣體(ti)徘(pai)出(chu),氣體(ti)經(jing)四通(tong)閥(fa)進入(ru)室外(wai)換熱(re)器放(fang)熱冷(leng)凝,成(cheng)為過(guo)冷(leng)液(ye)。
過(guo)冷(leng)液(ye)經毛細管阻(zu)力降(jiang)壓(ya)後成(cheng)為低(di)溫低(di)壓(ya)兩相流體,進入(ru)室內(nei)換熱(re)器蒸(zheng)發吸(xi)熱(re)(此(ci)時室(shi)內(nei)空(kong)氣被(bei)降溫),再壹(yi)次(ci)經(jing)四(si)通(tong)閥(fa)和(he)氣液(ye)分離(li)器進入(ru)下(xia)壹(yi)循(xun)環(huan):過(guo)濾器主要用(yong)於(yu)制冷(leng)劑與壓縮機油(you)的(de)分離(li),以保證換(huan)熱器的換熱效(xiao)率(lv)。
當(dang)熱(re)泵(beng)型空(kong)調機運行於(yu)制熱工(gong)況時(shi),四(si)通(tong)閥(fa)換向(xiang)使(shi)圖中虛(xu)線(xian)接通(tong)。這(zhe)時、室(shi)內(nei)換(huan)熱器成(cheng)為冷(leng)凝器,室外換熱(re)器成(cheng)為蒸(zheng)發器。從(cong)室(shi)外(wai)換(huan)熱器來(lai)的低(di)溫低(di)壓(ya)過(guo)熱(re)氣經(jing)四(si)通(tong)閥(fa)和(he)消(xiao)聲(sheng)器進入(ru)氣液(ye)分離(li)器,分離(li)出液(ye)體後,幹過(guo)熱(re)氣被(bei)壓縮機吸(xi)入(ru)壓縮成(cheng)為高(gao)溫高(gao)壓的(de)氣體(ti)徘(pai)出(chu),氣體(ti)經(jing)四通(tong)閥(fa)進入(ru)室內(nei)換熱(re)器放(fang)熱冷(leng)凝(此(ci)時,室(shi)內(nei)空(kong)氣被(bei)加(jia)熱(re)).成(cheng)為過(guo)冷(leng)液(ye),過(guo)冷(leng)液(ye)經毛細管阻(zu)力降(jiang)壓(ya)後成(cheng)為低(di)溫低(di)壓(ya)兩相流體.進入(ru)室外(wai)換熱(re)器蒸(zheng)發吸(xi)熱(re),隨後過(guo)熱(re)氣經(jing)四(si)通(tong)閥(fa)和(he)氣液(ye)分離(li)器進入(ru)下(xia)壹(yi)循(xun)環(huan)。
東(dong)營百(bai)科特(te)奧(ao)2P防爆空調(tiao)BFKG-5.0、東(dong)營2匹(pi)防爆空調(tiao)廠(chang)家(jia)。為防止制熱時(shi)因除霜(shuang)導致室內舒(shu)適(shi)性(xing)下(xia)降(jiang),采用(yong)了熱氣旁(pang)通(tong)不(bu)間(jian)斷(duan)制熱(re)除(chu)霜(shuang)方式(shi)。除(chu)霜(shuang)時,運行原理基本(ben)與制熱(re)相(xiang)同,只是將(jiang)融(rong)霜(shuang)電磁(ci)閥(fa)打開。從(cong)壓(ya)縮機出(chu)來(lai)的高(gao)溫高(gao)壓的(de)過(guo)熱(re)氣有壹(yi)部分(fen)被(bei)分流(liu)到(dao)室(shi)外換熱(re)器的入(ru)口(kou),迅速(su)把(ba)室(shi)外(wai)換熱器的溫度提(ti)高(gao)到O℃以(yi)上,融(rong)掉(diao)室外換熱(re)器上的霜(shuang)層,使(shi)換(huan)熱(re)器保持(chi)良(liang)好的(de)換(huan)熱(re)效(xiao)率(lv)。
櫃(gui)式(shi)防爆空調(tiao)如(ru)何(he)降噪(zao),在(zai)壹(yi)般(ban)判斷和(he)確(que)定防爆空調(tiao)制(zhi)冷(leng)效(xiao)果(guo)的好(hao)壞(huai)的(de)通(tong)常采用(yong)測量(liang)空調(tiao)結(jie)束(shu)後的(de)溫差(cha)來(lai)判斷。確(que)定方法是把(ba)空(kong)調設(she)定為高(gao)檔狀態(tai),空(kong)調(tiao)運行13分鐘後,再去(qu)用(yong)感溫探(tan)頭(tou)離(li)出風(feng)口(kou)10cm的地方測量(liang)溫差(cha)。


上壹(yi)篇(pian):3P防爆空調(tiao)BFKT-7.5棗(zao)莊防爆空調(tiao)|壁(bi)掛(gua)式(shi)/3匹(pi)
下(xia)壹(yi)篇(pian):3P防爆空調(tiao)BFKG-7.5煙臺(tai)3匹(pi)防爆空調(tiao)